CA402 CAST adrešu temperatūras detektors (aug, fiksēts 60º, 80º), ar izolatoru

Cenna: 24,44 €
Produkta numurs: 0-0223-014-000030
Ražotājs: C-TEC C-TEC
Kategorijas Detektori
Izpārdošana
24.44 EUR
Gatavs izsūtīšanai
Daudzums:
minus plus
Daudzums:
- +
Approvals/certifications
Certified to EN54-5 & 17 by the LPCB.
CompatibilityCompatible with C-TEC's XFP/ZFP CAST Protocol Addressable Fire Panels.
Type
Heat. Can be programmed as a Class A1R, Class A2 or Class B Heat Detector.
Application temperature25°C typical, 50°C max (in Class A1R and Class A2 mode); 40°C typical, 65°C max (in Class B mode). In A1R mode the detector will also trigger if it detects a sudden rise in temperature.
Static response temperature54°C min, 65°C max (In Class A1R and Class A2 mode); 69°C typical, 85°C max (in Class B mode).
SensitivityOption to set 3 different sensitvity levels at the fire panel. See Operation Modes tab below for details.
Supply wiring2-wire, polarity sensitive.
Supply/operating voltage27 to 40V DC.
Quiescent current370µA @ 35V DC.
Alarm current5mA (LEDs illuminated).
Indicators2 LED indicator strips emitting red light when in alarm offering 360º visibility. Optional remote LED.
ConnectionsVia CA408 base: 1 +Ve IN (analogue swich); 2 +Ve OUT (analogue switch); 3 Remote LED +Ve; 4 0V; 5 0V; 6 Screen; 7 Screen.
Product dimensions (mm)102.2mm diameter x 37mm deep (detector only); 102.2mm diameter x 57.5mm deep (detector in base).
Construction & finishWhite polycarbonate casing rated to UL94 V-2 with nylon parts.
IP RatingIP42.
Weight99g (not in base); 154g (in base).
Operating conditions/temperature-20ºC to +85ºC.
NotesRequires a CA408 CAST base. CA408R relay base also available.



Ir noliktavā
Īpašs piedāvājums Išpardavimas

Piegāde mājās (ieteicams)
Pēc preču nodošanas kurjeram informēsim Jūs pa e-pastu. pa pastu

līdz 5 kg 3,99 € līdz 10 kg 5,00 €
līdz 30 kg 9,00 € līdz 75 kg 15,00 €
līdz 200 kg 70,00 € līdz 1000 kg 200,00 €

Approvals/certifications
Certified to EN54-5 & 17 by the LPCB.
CompatibilityCompatible with C-TEC's XFP/ZFP CAST Protocol Addressable Fire Panels.
Type
Heat. Can be programmed as a Class A1R, Class A2 or Class B Heat Detector.
Application temperature25°C typical, 50°C max (in Class A1R and Class A2 mode); 40°C typical, 65°C max (in Class B mode). In A1R mode the detector will also trigger if it detects a sudden rise in temperature.
Static response temperature54°C min, 65°C max (In Class A1R and Class A2 mode); 69°C typical, 85°C max (in Class B mode).
SensitivityOption to set 3 different sensitvity levels at the fire panel. See Operation Modes tab below for details.
Supply wiring2-wire, polarity sensitive.
Supply/operating voltage27 to 40V DC.
Quiescent current370µA @ 35V DC.
Alarm current5mA (LEDs illuminated).
Indicators2 LED indicator strips emitting red light when in alarm offering 360º visibility. Optional remote LED.
ConnectionsVia CA408 base: 1 +Ve IN (analogue swich); 2 +Ve OUT (analogue switch); 3 Remote LED +Ve; 4 0V; 5 0V; 6 Screen; 7 Screen.
Product dimensions (mm)102.2mm diameter x 37mm deep (detector only); 102.2mm diameter x 57.5mm deep (detector in base).
Construction & finishWhite polycarbonate casing rated to UL94 V-2 with nylon parts.
IP RatingIP42.
Weight99g (not in base); 154g (in base).
Operating conditions/temperature-20ºC to +85ºC.
NotesRequires a CA408 CAST base. CA408R relay base also available.



Ir noliktavā
Īpašs piedāvājums Išpardavimas

Piegāde mājās (ieteicams)
Pēc preču nodošanas kurjeram informēsim Jūs pa e-pastu. pa pastu

līdz 5 kg 3,99 € līdz 10 kg 5,00 €
līdz 30 kg 9,00 € līdz 75 kg 15,00 €
līdz 200 kg 70,00 € līdz 1000 kg 200,00 €

Alternatīvas