STS/CKD+ Enhanced Calibration Keypad with 7 Digit Display

Price: 324,28 €
Product number: 0-0311-126-000010
Manufacturer CROWCON CROWCON
Category Control panels
324.28 EUR
This item is not on stock and has to be re-ordered.
Quantity:
minus plus
Quantity:
- +

Handhelp Enhanced calibration keypad to be connected to the detector SMART3 Sensitron to adjust the Zero, Span and 4-20mA values STS/CKD+


It can be connected to SENSITRON’S SMART detectors to adjust the Zero, Span and 4-20 mA values. Via the SD-CARD it is also possible to update detector’s firmware.


The calibration keypad STG can be used for all the gas detectors of Sensitron s.r.l.

The calibration keypad is supplied with an adapter for connection to SMART P detectors.

The calibration keypad enables the following (The mentioned operations are function of the gas detector in use) :


  • Zero calibration;
  • Span calibration;
  • 4-20 ma output calibration;
  • To change the alarm thresholds and its hysteresis;
  • To reset the device;
  • To couple detector with the sensor head “Head pairing”;
  • To change or visualize only the Baud Rate;
  • To set the address of the RS485 bus;
  • To show the firmware version of the detector.
Manufacturer CROWCON
Home delivery (recommended)

You will get an e-mail with parcel ID, once the goods are sent out

up to 5 kg 3,99 € up to 10 kg 5,00 €
up to 30 kg 9,00 € up to 75 kg 15,00 €
up to 200 kg 70,00 € up to 1000 kg 200,00 €

Handhelp Enhanced calibration keypad to be connected to the detector SMART3 Sensitron to adjust the Zero, Span and 4-20mA values STS/CKD+


It can be connected to SENSITRON’S SMART detectors to adjust the Zero, Span and 4-20 mA values. Via the SD-CARD it is also possible to update detector’s firmware.


The calibration keypad STG can be used for all the gas detectors of Sensitron s.r.l.

The calibration keypad is supplied with an adapter for connection to SMART P detectors.

The calibration keypad enables the following (The mentioned operations are function of the gas detector in use) :


  • Zero calibration;
  • Span calibration;
  • 4-20 ma output calibration;
  • To change the alarm thresholds and its hysteresis;
  • To reset the device;
  • To couple detector with the sensor head “Head pairing”;
  • To change or visualize only the Baud Rate;
  • To set the address of the RS485 bus;
  • To show the firmware version of the detector.

Manufacturer CROWCON

Home delivery (recommended)

You will get an e-mail with parcel ID, once the goods are sent out

up to 5 kg 3,99 € up to 10 kg 5,00 €
up to 30 kg 9,00 € up to 75 kg 15,00 €
up to 200 kg 70,00 € up to 1000 kg 200,00 €