Cable type: Telecommunication cable
Voltage test: 1500 V AC / DC 2250V
Insulation resistance: min 500 MΩ / km
Performance: 150 nF / km
Operating temperature: -25 ℃ to 70 ℃
Application conditions: Use in areas protected by sprayers
Minimum laying temperature: -5 ℃
Environmental resistance:
Halogen-free
No flame spreads with a single cable
The flame does not spread on the weave of the cables
Maintenance of electrical functions in the event of fire (EN 50200, DIN 4102-12)
Certificates / Approval / Approval:
CNBOP
Cable construction:
Core material: copper core
Construction of service cables: Class 1 (according to EN 60228, IEC 60228)
Screen: Foil screen
Application: Halogen-free fire telecommunication cables for use in emergency lighting equipment, alarm, signalling, telegraph systems, voice alarm systems (DSO), as well as fire alarm systems and fire automation and other safety circuits. The static shield (Eqw) protects the wires from the effects of external magnetic fields. In the event of a fire, these cables ensure proper operation of the unit for at least 90 minutes. (PH90) and cable insulation durability 3h (FE180). They do not emit toxic gases or dense smoke during combustion. The cables are suitable for permanent installation inside buildings. HTKSHekw FE180 / PH90 (E90) cables have been tested in accordance with DIN 4102 Part 12 and can be installed in E90 cable trays as part of an E90 cable assembly (assembly)
on the handles every 30 or 60 cm).
Cable features:
Manufacturer | BITNER |
You will get an e-mail with parcel ID, once the goods are sent out
up to 5 kg | 3,99 € | up to 10 kg | 5,00 € |
up to 30 kg | 9,00 € | up to 75 kg | 15,00 € |
up to 200 kg | 70,00 € | up to 1000 kg | 200,00 € |
Cable type: Telecommunication cable
Voltage test: 1500 V AC / DC 2250V
Insulation resistance: min 500 MΩ / km
Performance: 150 nF / km
Operating temperature: -25 ℃ to 70 ℃
Application conditions: Use in areas protected by sprayers
Minimum laying temperature: -5 ℃
Environmental resistance:
Halogen-free
No flame spreads with a single cable
The flame does not spread on the weave of the cables
Maintenance of electrical functions in the event of fire (EN 50200, DIN 4102-12)
Certificates / Approval / Approval:
CNBOP
Cable construction:
Core material: copper core
Construction of service cables: Class 1 (according to EN 60228, IEC 60228)
Screen: Foil screen
Application: Halogen-free fire telecommunication cables for use in emergency lighting equipment, alarm, signalling, telegraph systems, voice alarm systems (DSO), as well as fire alarm systems and fire automation and other safety circuits. The static shield (Eqw) protects the wires from the effects of external magnetic fields. In the event of a fire, these cables ensure proper operation of the unit for at least 90 minutes. (PH90) and cable insulation durability 3h (FE180). They do not emit toxic gases or dense smoke during combustion. The cables are suitable for permanent installation inside buildings. HTKSHekw FE180 / PH90 (E90) cables have been tested in accordance with DIN 4102 Part 12 and can be installed in E90 cable trays as part of an E90 cable assembly (assembly)
on the handles every 30 or 60 cm).
Cable features:
Manufacturer | BITNER |
You will get an e-mail with parcel ID, once the goods are sent out
up to 5 kg | 3,99 € | up to 10 kg | 5,00 € |
up to 30 kg | 9,00 € | up to 75 kg | 15,00 € |
up to 200 kg | 70,00 € | up to 1000 kg | 200,00 € |