Bitner 1 x 2 x ø0.8 fire protection cable YnTKSYekw

Special cables for connections of telephone switchboards and data transmission devices, using analogue and digital signals for control and fire alarm installations. Cables are used mainly as transmission lines and power line for fire alarm systems' devices (sensors, linear modules) and for autonomous fire fighting control systems and smoke extraction systems. Cables are suitable for installations used at the „0” moment of fire detection (moment of fire detection by the fire detection centre). Cables are intended for transmission of signal to auxiliary devices, which in case of fire detection are run by the central fire alarm (power cut-off, bringing down the lifts/elevators, ventilation cut-off) . Electrostatic screen protects the cables against external electromagnetic fields' interferences. Cables classified according toEN 50575 (CPR).

  • Conductors: solid copper conductor, class 1
  • Insulation: special PVC
  • Core colours: acc. PN-92/T-90320 (90321)
  • Core arrangement: cores twisted in pairs, pairs twisted together
  • Screen: aluminium backed polyester tape with tinned copper drain wire
  • Outer sheath: special PVC, highly flame retardant and self-extinguishing EN 60332-1, EN 60332-3-24, IEC 60332-3-24, cat. C), oxygen index >29; colour: red
More information and user manuals can be found in the "Downloads" section.
Manufacturer BITNER
Home delivery (recommended)

You will get an e-mail with parcel ID, once the goods are sent out

up to 5 kg 3,99 € up to 10 kg 5,00 €
up to 30 kg 9,00 € up to 75 kg 15,00 €
up to 200 kg 70,00 € up to 1000 kg 200,00 €

Bitner 1 x 2 x ø0.8 fire protection cable YnTKSYekw

Special cables for connections of telephone switchboards and data transmission devices, using analogue and digital signals for control and fire alarm installations. Cables are used mainly as transmission lines and power line for fire alarm systems' devices (sensors, linear modules) and for autonomous fire fighting control systems and smoke extraction systems. Cables are suitable for installations used at the „0” moment of fire detection (moment of fire detection by the fire detection centre). Cables are intended for transmission of signal to auxiliary devices, which in case of fire detection are run by the central fire alarm (power cut-off, bringing down the lifts/elevators, ventilation cut-off) . Electrostatic screen protects the cables against external electromagnetic fields' interferences. Cables classified according toEN 50575 (CPR).

  • Conductors: solid copper conductor, class 1
  • Insulation: special PVC
  • Core colours: acc. PN-92/T-90320 (90321)
  • Core arrangement: cores twisted in pairs, pairs twisted together
  • Screen: aluminium backed polyester tape with tinned copper drain wire
  • Outer sheath: special PVC, highly flame retardant and self-extinguishing EN 60332-1, EN 60332-3-24, IEC 60332-3-24, cat. C), oxygen index >29; colour: red
More information and user manuals can be found in the "Downloads" section.

Manufacturer BITNER

Home delivery (recommended)

You will get an e-mail with parcel ID, once the goods are sent out

up to 5 kg 3,99 € up to 10 kg 5,00 €
up to 30 kg 9,00 € up to 75 kg 15,00 €
up to 200 kg 70,00 € up to 1000 kg 200,00 €

Accessories

Alternatives